product reference

From the page to a confirmed order.

document intake

Reads what a lab receives, drafts what the order needs.

A document arrives in whatever condition the sender chose. Identity and insurance are read in the same pass — no per-clinic template to set up first.

FAX 03/12 07:52 · P.1/3 · NORTHGATENorthgate ClinicLABORATORY REQUISITION · REQ 4471-BWHITFIELD, DANA R.DOBN. OKAFOR, MDTSH REFLEXCASCADE MUTUAL HEALTHMEMBERDRAFTED ORDERPATIENTNAMEWHITFIELD, DANA R.SEXFDATE OF BIRTH11 / 04 / 1971CONTACT AND ADDRESS418 LARKSPUR AVE · (206) 555-0148IDENTIFIERSPATIENT ID / MRN44-812-097NATIONAL ID / PASSPORT / LICENCEDL W-4419-8827ORDERREFERRING ORGANISATION AND PROVIDERNORTHGATE CLINIC · N. OKAFOR, MDCOLLECTED03 / 12 07:40CLINICALTESTS AND PANELS, AS WRITTENCMP · TSH REFLEX · CBC W/ DIFFICD-10E11.9 · R73.03ASK-ON-ORDER-ENTRYFASTING — 12 HPRIORITYROUTINEINSURANCEPAYERCASCADE MUTUAL HEALTHPOSITIONPRIMARYMEMBER / POLICY NO.8842-QX-1130GROUP / GROUP NO.NG-TEAM / 55218PDF · JPG · PNG · TIFF · MULTI-PAGEREADS LEAST RELIABLYFAX 03/12 07:52 · P.1/3Northgate ClinicLABORATORY REQUISITION · REQ 4471-BDRAFTED ORDERPATIENT · NAME, SEX, ADDRESSWHITFIELD, DANA R.DATE OF BIRTH11 / 04 / 1971TESTS AND PANELS, AS WRITTENCMP · TSH REFLEXINSURANCE · PAYER, GROUPCASCADE MUTUAL HEALTHMEMBER / POLICY NO.8842-QX-1130READS LEAST RELIABLY

review and confidence

Scores the read. It never approves it.

The score is the model’s certainty about its own reading. It gives the technician confidence; it never gives the software authority.

Before a lab loads anything, on paper the model has never seen, roughly six fields in ten come back needing no correction. With a test list and referring-client codes in place that typically reaches the high eighties. The figure that counts is the one measured on the lab’s own documents — which is what the first batch is for.

SOURCEDRAFTEDCONFIRMWHITFIELD, D.DATE OF BIRTHTSH REFLEXMEMBER NO.

what it accepts

However it turns up.

Requisitions, insurance cards and identity documents — whatever condition the sender chose. PDF, JPG, PNG or TIFF, one page or many.

FAXEDHANDWRITTENPHONE PHOTOFLATBED SCANINSURANCE CARDLICENCE / IDFAXEDHANDWRITTENPHONE PHOTOFLATBED SCANINSURANCE CARDLICENCE / ID

batch processing

Batches in, worklists out.

One submission runs as a background job — no tab to keep open. A page that cannot be read becomes its own item instead of holding the batch behind it.

ONE SUBMISSIONNORTHGATE_FAX_0312.pdf14 pagesIMG_4471.HEICphotoscan_batch_a.tif9 pagesWESTLAKE_REQ.pdf6 pagesfront_desk_scan.pdf3 pagesONE WORKLISTWHITFIELD, DANA R.drafted · 19 fieldsOYELARAN, TOBIdrafted · 17 fieldspage 7 — unreadableits own itemCHEN, MEILINdrafted · 19 fieldsONE SUBMISSIONNORTHGATE_FAX_0312.pdf14 pagesIMG_4471.HEICphotoscan_batch_a.tif9 pagesWESTLAKE_REQ.pdf6 pagesfront_desk_scan.pdf3 pagesONE WORKLISTWHITFIELD, DANA R.drafted · 19 fieldsOYELARAN, TOBIdrafted · 17 fieldspage 7 — unreadableits own itemCHEN, MEILINdrafted · 19 fields

inside the LIS

A confirmed order, already in the system.

The order is created in CrelioHealth, where accessioning already happens — no export file, no second system, no re-keying. Tests land on the lab’s own test list, and the referring client and physician on its own masters.

Duplicate checkAudit trailReady to accession

AiReq owns whether the order matches its documents. Whether a payer accepts it is Revenue Guard.

any other LIS

On a different system, the order still gets out.

The read is the same whichever system a lab runs; only the way out changes.

API
A document goes in; the drafted order comes back as structured JSON. Sandbox and live keys are kept apart.
Webhook
A signal the moment a read completes or fails, so the receiving system can collect it.
CSV
Any requisition’s fields as a spreadsheet, one download each.
HL7 and FHIR
Not available today. Which LIS a lab runs is settled before it signs up, not after.

toxicology

Medications, test by test.

Screening, confirmation and prescribed drugs are read against the test they belong to. On the CrelioHealth registration screen they attach from the lab’s own drug and brand lists, metabolites included.

molecular and PCR

Panels, read as written.

Respiratory, UTI and STI panels are read off the form and matched to the lab’s own test list by name and code — the list the lab already keeps, with nothing rebuilt for AiReq.

clinical and routine

The whole order, codes included.

Chemistry, hematology and routine orders are read with the diagnosis codes, insurance and collection date on the form. On the CrelioHealth registration screen all three carry into the order.

try it yourself

See it read your own requisitions.

Send a stack of your own forms — whatever turns up — and we'll show you what came back, field by field, including what it got wrong.

security

A signed BAA, 30-day retention, and a person on every order.

BAA